LoE-180

Technical Performance Data

Center-of-Glass Performance VISIBLE LIGHT FADING SHGC U-FACTOR (IP / SI)
Transmission Exterior UV ISO Air Fill Argon Fill
Clear / LoE-180
3/4" Dual Pane
79% 15% 29% 63% 0.69 0.31 / 1.74 0.26 / 1.49
LoE-180 / LoE-i89
3/4" Dual Pane
77% 15% 27% 61% 0.62 0.24 / 1.37 0.21 / 1.19
LoE-180 / Clear / LoE-180
1" Triple Pane
70% 20% 13% 50% 0.56 0.17 / 0.94 0.13 / 0.75
LoE-180 / LoE-180 / LoE-i89
1" Triple Pane
68% 21% 13% 49% 0.53 0.14 / 0.81 0.12 / 0.66

* Performance data based on NFRC simulation standards (Window 7.x / Therm 7.x). Center-of-glass values shown. Actual total unit performance may vary based on frame type and spacer selection. Solar Heat Gain Coefficient (SHGC) represents the fraction of incident solar radiation that actually enters a building. U-Value measures the rate of non-solar heat loss/gain. Lower U-Values represent better insulating performance.

Center-of-Glass Performance Transmission Exterior

* NFRC simulation standards. Center-of-glass values shown.